Hi,
On Tue, 17 Apr 2001, Vinod Anthony Joseph Cherunni wrote:
> Hi,
>
> Thanks a lot for the valuble suggestions. I really understand your point,
> on allocating a seperate E1 for PRI access, & leased line access. I am
> facing a situation wherein I would need to have a multi-link bundle of 2
> "B" channels as a backup circuit, & another multi-link bundle of 2 "B"
> channels for another connection to a central office, Both which need to be
> part of the same PRI circuit. I understand that "Dialer Profiles" is the
> way to go. But I am still a bit unclear on whether this config will work.
>
[snipp]
> Kindly advise me on whether this config will achieve the required.
sorry can't find the time to immediately look through your config
>
> One last question, since this is a PRI line, & I would only like to use 2
> "B" channels at maximum per multi-link bundle. Is there any special config
> to restrict the number of "B" channels to brought up per "dialer"
> interface.
I think this should work with a virtual template
Somehting like this
!
interface Virtual-Template1
ip unnumbered Serial1/0:15
ppp multilink
multilink max-links 2
multilink min-links 1
multilink load-threshold 128 outbound
!
Greetings
Christian
-- TopLink Internet Services GmbH ck@171.2.195.in-addr.arpa Christian Kratzer http://www.toplink.net/ Phone: +49 7032 2701-0 Fax: +49 7032 2701-19 FreeBSD spoken here!