[nsp] Trapped in a loop

From: Michael Graves (mgraves@cvvt.org)
Date: Wed Apr 25 2001 - 10:45:52 EDT


For NANOG, non-operational content

One of my instructors has a Cisco 2501 running 12.0(9) that is possessed.
A) Have you ever seen this before
B) Do you know how to stop it.

A student added an IP address to S1 and the router went postal.
>From the terminal session:

Nested r4k_return_to_monitor call (4165 times)

-Traceback= 0 31B985C

Nested r4k_return_to_monitor call (4166 times)

-Traceback= 0 31B985C

Nested r4k_return_to_monitor call (4167 times)

-Traceback= 0 31B985C

Nested r4k_return_to_monitor call (4168 times)

-Traceback= 0 31B985C

Nested r4k_return_to_monitor call (4169 times)

-Traceback= 0 31B985C

Nested r4k_return_to_monitor call (4170 times)

-Traceback= 0 31B985C

The counter increments until you reboot, then starts counting again.

Cisco lists the following in the IOS notes:
CSCdr75021
As a Cisco router boots Cisco IOS, it attempts to read the CPU EEPROM into a
data structure that is not big enough, causing the router to reload. The
crash dump typically looks like this:
Nested r4k_return_to_monitor call (2 times) -Traceback= 0 6038EC00 6038EB14
6038D524 603768D4 6042C86C 6042BF88 6043866C 604379CC 6042EB18 Nested
r4k_return_to_monitor call (3 times) *** System received a Bus Error
exception *** signal= 0xa, code= 0x4008, context= 0x61869b70 PC =
0x60431200, Cause = 0x4020, Status Reg = 0x34008002 rommon 2 >
There is no workaround.

I would appreciate any help

Mike

-------------------------------------------------------------------
      | | | Michael Graves CCNA CCAI
     :|: :|: | Cisco Regional Trainer
    :|||: :|||: | Canadian Valley Technology Center
 .:|||||||:..:|||||||:. | 6505 East Highway 66
C i s c o S y s t e m s | El Reno, Ok 73036
Network Academy Program | (voice)405.422.2327
    Are You Ready ? | (fax)405.422.2354
-------------------------------------------------------------------