Ensure you don't have mem-dumb files or something clogging up you nvram. can
you copy the start-up to the running?
copy start runn
Jon..
-----Original Message-----
From: Jared Mauch [mailto:jared@puck.nether.net]
Sent: 30 April 2001 15:57
To: Brian Murphy
Cc: dine@swiftkenya.com; 'Cisco-Nsp'
Subject: Re: No running configuration
On Mon, Apr 30, 2001 at 04:48:09PM +0200, Brian Murphy wrote:
> Dine,
> Can you please supply a copy of the configuration, minus passwords
> etc......
You seem to be missing the fact that when "sh run" is issued
nothing is displayed.
I would recommend doing this:
clear ip route *
That should sufficently defragment the memory that
you can issue "sh run" and "wr" or whatever commands you use
to save your config.
- jared
> -----Original Message-----
> From: Dragan Dincic - Dine [mailto:dine@swiftkenya.com]
> Sent: Monday, April 30, 2001 3:58 PM
> To: BrianM@dial.pipex.com; 'Cisco-Nsp'
> Subject: RE: No running configuration
>
> I have seen now that I'm missing that info...
>
> cisco 3640 (R4700) processor (revision 0x00) with
27648K/5120K bytes of
> memory.
> 8192K bytes of processor board System flash (Read/Write)
>
> Which is exactly what CISCO is recommending...
>
>
> dine
>
>
>
>
> -----Original Message-----
> From: Brian Murphy [mailto:BrianM@dial.pipex.com]
> Sent: Monday, April 30, 2001 16:54
> To: dine@swiftkenya.com; 'Cisco-Nsp'
> Subject: RE: No running configuration
>
>
> Dragan Dincic - Dine,
> There is some critical information missing from the show version you
> included in your previous email, but according to cisco the memory
> requirements for your IOS and platform are as follows:
>
>
> Minimum Recommended Memory to download image - 8 MB Flash and
32 MB RAM
>
>
> -----Original Message-----
> From: Dragan Dincic - Dine [mailto:dine@swiftkenya.com]
> Sent: Monday, April 30, 2001 3:42 PM
> To: Cisco-Nsp
> Subject: No running configuration
>
> Has anybody experienced this:
> When you do the "sh running-config " - there is no running
> configuration.
> If you issue "sh startup-config " - configuration is there.
>
> just terminal monitor reveals following:
> 02:45:27: %SYS-2-MALLOCFAIL: Memory allocation of 129016 bytes failed
> from
> 0x60239AD8, pool Processor, alignment 0
>
> -Process= "Virtual Exec", ipl= 0, pid= 54
> -Traceback= 602AC974 602AE3F8 60239AE0 6025AA50 60251EE4 6025D45C
> 602A3F2C
> 602A3F18h flas
>
> PID
> [54 130 54836 52420 15272 0 0 Virtual
> Exec]
>
> If I try to copy startup into the running configuration I
get following
> error:
>
> %Error opening system:/running-config (Not enough space)
>
>
> Below is the version of the IOS that I'm running and memory
> configuration.
>
> #sh ver
> Cisco Internetwork Operating System Software
> IOS (tm) 3600 Software (C3640-IS-M), Version 12.0(4)T,
RELEASE SOFTWARE
> (fc1)
> System image file is "flash:c3640-is-mz.120-4.T.bin"
>
> 2 Ethernet/IEEE 802.3 interface(s)
> 46 Serial network interface(s)
> 2 Channelized E1/PRI port(s)
> DRAM configuration is 64 bits wide with parity disabled.
> 125K bytes of non-volatile configuration memory.
> 8192K bytes of processor board System flash (Read/Write)
>
> Configuration register is 0x2102
>
>
>
>
>
>
> Dragan Dincic - Dine
> Technical Manager
> Swift Global (K) Ltd.
> dine@swiftkenya.com
> ==============
> P.O. BOX 42164
> Nairobi, KENYA
> ~~~~~~~~~~~~~~
> Tel : +254 2 545 533
> Fax : +254 2 545 534
> ~~~~~~~~~~~~~~
>
-- Jared Mauch | pgp key available via finger from jared@puck.nether.net clue++; | http://puck.nether.net/~jared/ My statements are only mine.********************************************************************** COLT Telecommunications Registered in England No. 2452736 Registered Office: Bishopsgate Court, 4 Norton Folgate, London E1 6DQ Tel. 020 7390 3900
This message is subject to and does not create or vary any contractual relationship between COLT Telecommunications, its subsidiaries or affiliates ("COLT") and you. Internet communications are not secure and therefore COLT does not accept legal responsibility for the contents of this message. Any view or opinions expressed are those of the author. The message is intended for the addressee only and its contents and any attached files are strictly confidential. If you have received it in error, please telephone the number above. Thank you.
**********************************************************************
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:36 EDT