Has anybody experienced this:
When you do the "sh running-config " - there is no running configuration.
If you issue "sh startup-config " - configuration is there.
just terminal monitor reveals following:
02:45:27: %SYS-2-MALLOCFAIL: Memory allocation of 129016 bytes failed from
0x60239AD8, pool Processor, alignment 0
-Process= "Virtual Exec", ipl= 0, pid= 54
-Traceback= 602AC974 602AE3F8 60239AE0 6025AA50 60251EE4 6025D45C 602A3F2C
602A3F18h flas
PID
[54 130 54836 52420 15272 0 0 Virtual Exec]
If I try to copy startup into the running configuration I get following
error:
%Error opening system:/running-config (Not enough space)
Below is the version of the IOS that I'm running and memory configuration.
#sh ver
Cisco Internetwork Operating System Software
IOS (tm) 3600 Software (C3640-IS-M), Version 12.0(4)T, RELEASE SOFTWARE
(fc1)
System image file is "flash:c3640-is-mz.120-4.T.bin"
2 Ethernet/IEEE 802.3 interface(s)
46 Serial network interface(s)
2 Channelized E1/PRI port(s)
DRAM configuration is 64 bits wide with parity disabled.
125K bytes of non-volatile configuration memory.
8192K bytes of processor board System flash (Read/Write)
Configuration register is 0x2102
Dragan Dincic – Dine
Technical Manager
Swift Global (K) Ltd.
dine@swiftkenya.com
==============
P.O. BOX 42164
Nairobi, KENYA
~~~~~~~~~~~~~~
Tel : +254 2 545 533
Fax : +254 2 545 534
~~~~~~~~~~~~~~
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:36 EDT