Re: [nsp] Terminating PtP E1 in 3660 - NM-4E1-IMA

From: Félix Izquierdo (fizquierdo@datagrama.net)
Date: Tue May 22 2001 - 07:38:04 EDT


Ray Davis wrote:

> Get some WIC slots (NM-2FE2W for example) and a couple of these:
>
> VWIC-1MFT-E1 1 x E1 structured
> VWIC-2MFT-E1 2 x E1 structured
> VWIC-1MFT-G703 1 x E1 unstructured (and structured?)
> VWIC-2MFT-G703 2 x E1 unstructured (and structured?)
>
> I'm not sure how many of these a 3660 can deal with. We have a 3662
> with one VWIC-2MFT-G703. It was supposed to replace a WIC-2T with
> external converters. It did replace one E1 unstructured line,
> although that line seems to go down/up periodically which it never
> used to do.

It seems CSCdt48393.

The -G703 WIC's can be used as strutured without problems.

Félix