RE: [nsp] [nsp] RSP8 amd Rec. Side Buffering (was: VIP if-con and IOS switching)

From: Alex Rubenstein (alex@nac.net)
Date: Wed May 30 2001 - 00:17:07 EDT


> Does RSP8 add 'bandwidth' to the CyBUS or do we need VIP4-80s to get 4Gbps
> (I seem to remember something about a CzBUS)? I want to see how far the
> 7513 can go.

My understanding, per a half-remembered cisco conversation, is that you
need an RSP8 + MIX enabled chassis + VIP4 to get the new 2 gb/s bus.

CHAS-7507-MX= Cisco 7507 MX-Enabled Chassis and AC Power Supply

You can still stick VIP2's in the MX chassis, but I dunno what happens to
the bus (does it slow down on that side?) if you do.

> Anyway, the important point to remember is that true distributed switching
> on the RSP platforms only occurs between PA's in the same VIP (unlike the
> GSR). InterVIP switching requires the RSP to manage access to MEMD between
> VIPs (hence the high amount of RSB drops when the load is high).

Granted, but if the packet is VIP to VIP with dCEF and it is Auton/SSE
switched, the packet never hits the RSP, at least thats what I remember.