[nsp] "interesting" error message

From: ken lindahl (lindahl@ack.Berkeley.EDU)
Date: Thu Jun 14 2001 - 17:59:25 EDT


hi,

does anyone have any pointers on the following error message:

2001 Jun 14 14:50:50 PDT -07:00 %SYS-3-SYS_LCPERR3:Module 4: Coil Pb Tx Underflow Error - Port #13:
2001 Jun 14 14:50:50 PDT -07:00 %SYS-3-SYS_LCPERR3:Module 4: Coil Pb Tx Underflow Error - Port #14:
2001 Jun 14 14:50:50 PDT -07:00 %SYS-3-SYS_LCPERR3:Module 4: Coil Pb Tx Underflow Error - Port #15:
2001 Jun 14 14:50:50 PDT -07:00 %SYS-3-SYS_LCPERR3:Module 4: Coil Pb Tx Underflow Error - Port #23:

this is happening on a catalyst 6506 w/sup2, pfc2, msfc2, running ver 6.1(2)
on the sup2. Module 4 is a 48-port 10/100 TX blade; there are identical
blades in slots 2, 3, and 5 that are not showing this problem. the error
appears to be affecting ports 13-23 on the blade, when it happens it happens
to several ports at the same time, but not always the same set of ports.

i can't find any reference to this error message on cisco's web pages.

thanks,
ken