If you want an ATM DS3 for the 3600, check out the NM-1A-T3 or NM-1A-E3 to
see if they fit your needs at:
http://www.cisco.com/warp/public/cc/pd/rt/3600/prodlit/brct_ds.htm
Ken W
-----Original Message-----
From: Gert Doering [mailto:gert@greenie.muc.de]
Sent: Tuesday, August 14, 2001 4:33 AM
To: Mikael Abrahamsson; cisco-nsp@puck.nether.net
Subject: Re: [nsp] T3/E3 koax
Hi,
On Tue, Aug 14, 2001 at 10:09:42AM +0200, Mikael Abrahamsson wrote:
> I need to terminate a koax delivered T3 with some cisco equipment. So far,
> we've been using HSSI interfaces with Kentrox DSUs. I still cannot find
> any native koax interfaces for 3600 or 7200. Am I missing something, or is
> there perhaps a new bundle? I found 7120-T3, but my dealer says that
> product will be discontinued.
For the 7200, look at the PA-T3/PA-2T3 boards (one or two T3 45Mbit
ports).
On the PA itself, it's labeled "DS3 port adaptor", but DS3 = T3.
We use a couple of them, and they work quite well. The only thing that's
better in the Kentroxes is that they can do E3 and T3, whatever you need.
But monitoring is much better on the PAs.
It's a pity that there is no such NM for the 36xx series. But that's
marketing, obviously - if the 3660 is a big success (and it has enough
horsepower to drive a few NM-E3s - after all, the NM-1Hssi exists) it
will cut into 7200 sales. I think this sucks, but so do many marketing-
driven decisions.
gert
-- USENET is *not* the non-clickable part of WWW! //www.muc.de/~gert/ Gert Doering - Munich, Germany gert@greenie.muc.de fax: +49-89-35655025 gert.doering@physik.tu-muenchen.de