Hi,
   I have a frame Relay PVC of 16 k CIR. My access
links at both end are E1. I need to configure class
based weighted fair queueing on this interface.
   Class Based Weighted fair queuing allows a
percentage of bandwdith to be configured per traffic
class. However, Since my access link is much higher
than the PVC, My router will keep on pumping data into
the FR network since the access speed is much higher
than the PVC.
   A solution to the above would be to confiugre FRTS.
However, FRTS does not support CBWFQ !
   Have any of you guys run into a similar problem
where you need to do a class based queuing on a frame
relay PVC ? I dont want to use multiple PVC's for
multiple classes of traffic.

 

__________________________________________________