RE: [nsp] CRC input errors

From: Sonya Gilly (sgilly@servicom2000.com)
Date: Fri Aug 17 2001 - 03:34:16 EDT


Hi Juan,

I have disabled keepalives in that interface and now there aren't new
errors.

Thank you very much.
Sonya Gilly

-----Mensaje original-----
De: Juan C. Verde [mailto:juanc.verde@inycom.es]
Enviado el: viernes, 17 de agosto de 2001 9:10
Para: Sonya Gilly
CC: Cisco-Nsp
Asunto: Re: [nsp] CRC input errors

Hi Sonya

> Sonya Gilly wrote:
>
> Hi,
>
> I have configured ISL between a 2924XL switch and a 3640 router (with
> FastEthernet interfaces). Since the begining I have seen CRC input
> errors in the switch's interface with ISL although the communication
> with the two VLANs is right. There are no errors in the 3640.

See if the rate of CRC errors is about 1 each 10 seconds; if so, try to
disable keepalives in the router's native FastEthernet interface.

Cheers
Juan C. Verde



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:49 EDT