RE: [j-nsp] =?gb2312?B?SG93IHRvIHVzZSBuZXRmbG93Q29sbGVjdG9yIHRvIGNvbGxlY3QgVjggZGF0YSBmcm9tIEp1

From: Robert O'Hara (rohara@juniper.net)
Date: Tue Oct 23 2001 - 22:49:51 EDT


Hello Huiy,
 
Is the Netflow Collector version 3.0 running on top of Solaris?
 
Please advise.
 
Thanks,
 
Bob O'Hara

Systems Engineer
Juniper Networks
Northeast Sales Region

.........................................
. email:rohara@juniper.net .
.........................................

-----Original Message-----
From: huiy [mailto:huiy@263.net]
Sent: Tuesday, October 23, 2001 9:42 PM
To: cisco-nsp@puck.nether.net
Subject: [j-nsp] =?gb2312?B?SG93IHRvIHVzZSBuZXRmbG93Q29sbGVjdG9yIHRvIGNvbGxlY3QgVjggZGF0YSBmcm9tIEp1

Hello,everyone.
I'd like to use Netflow Collector3.0(2.0) to collect RouterAS information
from Juniper routers.
The Version 8 Header Format Cisco is using is as follows:

0每1 version NetFlow export format version number
2每3 count Number of flows exported in this flow frame
4每7 SysUptime Current time in milliseconds since the export device booted
8每11 unix_secs Current seconds since 0000 UTC 1970
12每15 unix_nsecs Residual nanoseconds since 0000 UTC 1970
16每19 flow_sequence Sequence counter of total flows seen
20 engine_type Type of flow switching engine
21 engine_id ID number of the flow switching engine
22 aggregation Aggregation method being used
23 agg_version Version of the aggregation export
24每27 reserved Unused (zero) bytes

Cisco set agg_version to 2 now,but Juniper set agg_version to 0.
And the other field is the same.When Netflow Collector 3.0 receive
V8 data from Juniper rou! ters,it says "error engine_type" and discard
the data. Anyone knows how to solve this problem?
Thanks a lot!

---
H.Y Zhang.
Oct.24 2001

<http://advert.263.net/cgi-bin/advert/push/redirect.cgi?aid=3123>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:52 EDT