You should use 12.1(8a)E4
There is a long laundry-list of bugs that are fixed
between 12.1(3a)E4 and 8aE4.
- Jared
On Sat, Oct 27, 2001 at 08:41:08PM -0700, Bulger, Tim wrote:
> Anyone happen to have seen a nearly complete lockup of the RSM running
> 12.1(3a)E4? It seems that OSPF and HSRP continue to work correctly and
> traffic sourced from the CLI (such as pings and traceroutes) function fine,
> but servers on directly connected networks cannot ping the gateway and 90%
> percent of traffic is dropped with very typical CPU usage? A reboot is the
> only thing that seems to clear it up. Suggestions? :)
>
> cs1b-rtr#sh ver
> Cisco Internetwork Operating System Software
> IOS (tm) MSFC2 Software (C6MSFC2-IS-M), Version 12.1(3a)E4, EARLY DEPLOYMENT
> RELEASE SOFTWARE (fc1)
> Copyright (c) 1986-2000 by cisco Systems, Inc.
> Compiled Sat 14-Oct-00 01:16 by eaarmas
> Image text-base: 0x30008980, data-base: 0x30D60000
>
> ROM: System Bootstrap, Version 12.1(3r)E2, RELEASE SOFTWARE (fc1)
> BOOTFLASH: MSFC2 Software (C6MSFC2-BOOT-M), Version 12.1(3a)E4, EARLY
> DEPLOYMENT RELEASE SOFTWARE (fc1)
>
> cs1b-rtr uptime is 2 hours, 27 minutes
> System returned to ROM by power-on
> Running default software
>
> cisco Cat6k-MSFC2 (R7000) processor with 491520K/32768K bytes of memory.
> Processor board ID SAD05040SHV
> R7000 CPU at 300Mhz, Implementation 39, Rev 2.1, 256KB L2, 1024KB L3 Cache
> Last reset from power-on
> Bridging software.
> X.25 software, Version 3.0.0.
> 11 Virtual Ethernet/IEEE 802.3 interface(s)
> 509K bytes of non-volatile configuration memory.
>
> 16384K bytes of Flash internal SIMM (Sector size 512K).
> Configuration register is 0x2102
>
> Thanks,
>
> .: Tim Bulger ... .
> . : EA.com Network Engineering : .
> . ... [650] 628/5178 :.
-- Jared Mauch | pgp key available via finger from jared@puck.nether.net clue++; | http://puck.nether.net/~jared/ My statements are only mine.