[nsp] 6500+RSM lockup with 12.1(3a)E4?

From: Bulger, Tim (TBulger@ea.com)
Date: Sat Oct 27 2001 - 23:41:08 EDT


Anyone happen to have seen a nearly complete lockup of the RSM running
12.1(3a)E4? It seems that OSPF and HSRP continue to work correctly and
traffic sourced from the CLI (such as pings and traceroutes) function fine,
but servers on directly connected networks cannot ping the gateway and 90%
percent of traffic is dropped with very typical CPU usage? A reboot is the
only thing that seems to clear it up. Suggestions? :)

cs1b-rtr#sh ver
Cisco Internetwork Operating System Software
IOS (tm) MSFC2 Software (C6MSFC2-IS-M), Version 12.1(3a)E4, EARLY DEPLOYMENT
RELEASE SOFTWARE (fc1)
Copyright (c) 1986-2000 by cisco Systems, Inc.
Compiled Sat 14-Oct-00 01:16 by eaarmas
Image text-base: 0x30008980, data-base: 0x30D60000

ROM: System Bootstrap, Version 12.1(3r)E2, RELEASE SOFTWARE (fc1)
BOOTFLASH: MSFC2 Software (C6MSFC2-BOOT-M), Version 12.1(3a)E4, EARLY
DEPLOYMENT RELEASE SOFTWARE (fc1)

cs1b-rtr uptime is 2 hours, 27 minutes
System returned to ROM by power-on
Running default software

cisco Cat6k-MSFC2 (R7000) processor with 491520K/32768K bytes of memory.
Processor board ID SAD05040SHV
R7000 CPU at 300Mhz, Implementation 39, Rev 2.1, 256KB L2, 1024KB L3 Cache
Last reset from power-on
Bridging software.
X.25 software, Version 3.0.0.
11 Virtual Ethernet/IEEE 802.3 interface(s)
509K bytes of non-volatile configuration memory.

16384K bytes of Flash internal SIMM (Sector size 512K).
Configuration register is 0x2102

Thanks,

    .: Tim Bulger ... .
  . : EA.com Network Engineering : .
. ... [650] 628/5178 :.



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:21 EDT