> Hi Jon
>
> It's strange
> I have used the version on GSR 12016 for a long time,that's fine,no
> any problem
> What's difference between 12012 and 12016 ?
12012 is a 12-slot GSR, 12016 is a 16-slot GSR.
>
>
>
> > You need 12.015S2 at least.
3xport GE is supported from 12.0(11)S3.
> >
> > I have the same issue, try using 12.016S(thelatest) it works well.
> >
The latest is 12.0(19)S for the GSR.
Alex Yeung
> > Cheers
> > Jon
> >
> > -----Original Message-----
> > From: micky [mailto:micky@apol.com.tw]
> > Sent: 26 October 2001 11:24
> > To: cisco-nsp@puck.nether.net
> > Subject: [nsp] Cisco GSR12012 support 3port GE line card ?
> >
> >
> > Hi Mr.nsp
> >
> > My GSR12012 is running IOS ver 12.0.15s1
> > When I finished inserting the line card,I found card was detected by
> IOS
> > But the front panel led showed "up" ,not "run"
> > It's very strange,this caused GE port to be down
> >
> > Anyone about this condition ?
> >
> > Thanks
> > Have a nice weekend
> > Micky
> >
> >
> >
> >
> >
> >
> > **********************************************************************
> > COLT Telecommunications
> > Registered in England No. 2452736
> > Registered Office: Bishopsgate Court, 4 Norton Folgate, London E1 6DQ
> > Tel. 020 7390 3900
> >
> > This message is subject to and does not create or vary any contractual
> > relationship between COLT Telecommunications, its subsidiaries or
> > affiliates ("COLT") and you. Internet communications are not secure
> > and therefore COLT does not accept legal responsibility for the
> > contents of this message. Any view or opinions expressed are those of
> > the author. The message is intended for the addressee only and its
> > contents and any attached files are strictly confidential. If you have
> > received it in error, please telephone the number above. Thank you.
> >
> >
> > **********************************************************************
>
>
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:52 EDT