Fix your config off-line and do copy tftp startup-config, followed by
reload. May help.
On Thu, Nov 01, 2001 at 10:00:44AM -0600, Phil Bedard wrote:
> This is on a CT3 card on a 7513 running 12.0(10)S, for
> whatever reason doing a "show ip int brief" results in this:
>
> Serial1/0/0:15 10.10.10.10 YES NVRAM up up
> Serial1/0/0:16 10.10.10.10 YES NVRAM up up
> Serial1/0/0/-1:-1 unassigned YES manual down down
> Serial1/0/0:18 10.10.10.10 YES NVRAM up up
>
> You also can't do a specific show int of any of the serial interface on
> that CT3. IE: show int Serial1/0/0:18 gives an invalid input error. The
> other interfaces also can't be configured. Anyone seen this before?
---end quoted text---
SY,
-- CCNP, CCDP (R&S) Dmitri E. Kalintsev CDPlayer@irc Network Architect @ connect.com.au dek @ connect.com.au phone: +61 3 9674 3913 fax: 9251 3666 http://-UNAVAIL- UIN:7150410 cell: +61 414 821 382
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:53 EDT