Re: [nsp] E-BGP between PE-CE and loopback Address

From: Rick Burts (rburts@netcraftsmen.net)
Date: Fri Dec 14 2001 - 16:55:54 EST


Manpreet

some more detail of what you are trying to do would be helpful.
Are you peering to the physical interface address or to the loopback ?
If peering to the loopback you will need ebgp-multihop.
Have you tested IP reachability - the best test is an expended ping
which specifies the source as the BGP peering address of the local
router
and the destination as the BGP peering address of the remote router.
(It would be good to test from both sides)

can you give more detail - showing the relevant part of the configs
might also be helpful.

Rick

Manpreet Singh wrote:
>
> Hi all,
> i have E-BGP configured on the PE and the CE. PE-CE link is a serial
> link with frame-relay encapsulation (Static PVC configured).
> Also, on both PE and CE, we have loobbacks configured with host IP
> addresses from /30. The problem is that the CE and PE are not reachable
> from each other. Can anyone suggest why ?
>
> It's urgent,
>
> -Thanks in advance.
>
> Manpreet

-- 
Rick Burts     CCIE 4615  CCSI     Email: rburts@netcraftsmen.net 
Chesapeake NetCraftsmen            O:410.757.3050,  
1290 Bay Dale Drive,  #312         C:443.994.0675
Arnold, MD 21012-2325              WWW: http://www.netcraftsmen.net 

With 6 CCIEs on staff Chesapeake NetCraftsmen offers services in network consulting and training. Our services include Network Design, Implementation, Troubleshooting as well as Network Management.



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:57 EDT