Re: Nortel and Cisco

From: Josh Duffek (jduffek@cisco.com)
Date: Wed Jan 16 2002 - 13:21:23 EST


debug frame lmi would be good to look at. sh frame pvc too.

Josh

----- Original Message -----
From: "Akram, Israr" <IAkram@colt-telecom.com>
To: <cisco-nsp@puck.nether.net>
Sent: Wednesday, January 16, 2002 7:48 AM
Subject: Nortel and Cisco

> Has any one had any issues getting Nortel AN router to talk to Cisco 7206
> VXR over frame relay.Its not picking up the dlci.
>
> Below is the Serial interface config. on Cisco.
>
> interface Serial1/0/2:2
> no ip address
> no ip redirects
> no ip directed-broadcast
> no ip proxy-arp
> encapsulation frame-relay IETF
> no fair-queue
> frame-relay traffic-shaping
> frame-relay lmi-type ansi
> frame-relay intf-type dce
>
> interface Serial1/0/2:2.1 point-to-point
> bandwidth 1984
> ip address 10.10.1.0 255.255.255.252
> no ip redirects
> no ip directed-broadcast
> no ip proxy-arp
> ip mroute-cache
> no cdp enable
> frame-relay class 1984kgold
> frame-relay interface-dlci 16
>
>
>
> ***********************************************************************
> COLT Telecommunications
> Registered in England No. 2452736
> Registered Office: Bishopsgate Court, 4 Norton Folgate, London E1 6DQ
> Tel. 020 7390 3900
>
> This message is subject to and does not create or vary any contractual
> relationship between COLT Telecommunications, its subsidiaries or
> affiliates ("COLT") and you. Internet communications are not secure
> and therefore COLT does not accept legal responsibility for the
> contents of this message. Any view or opinions expressed are those of
> the author. The message is intended for the addressee only and its
> contents and any attached files are strictly confidential. If you have
> received it in error, please telephone the number above. Thank you.
>
> ***********************************************************************



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:59 EDT