Rolands@lattelekom.lv said:
> Is it possible to do statefull failover with using only one Ethernet
> link between two PIXes? Is it mandatory  to use serial (rs232) cable
> additional for that? If yes, is it possible to create "rsr232 link"
> extension  over IP using let say 2509 async ports? We want to put our
> PIXes in different sites.
The failover cable is more than a straight serial connection.  Some of the 
pins are looped back on each end to let the PIX know something about its 
failover partner.  Other pins use whether or not there is a signal on the 
line to indicate if the remote unit is powered, etc.  You might be able to 
jury-rig a cable, but you would likely "trick" the PIX into behaving badly 
during a failure.
I would probably say that if your architecture makes you want to put your 
PIXen at two different sites, then the architecture probably isn't well 
suited for the PIX.  Metro-Area Ethernet does introduce some interesting 
failover opportunities, but I'm not sure if the PIX is quite ready to 
handle that case yet.
-- David P. Maynard, CTO OutServ.net, Inc. -- Managed IT Operations Solutions for Business [TM] EMail: dmaynard@outserv.net, Tel: +1 512 977 8918, Fax: +1 512 977 0986 --
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:03 EDT