Hi , yes the interface 7 is connected to the primary pix by crossover
cable.
This interface is connected only back-to-back without traffic internet.
No, i didn't reboot the primary, but this morning i riceived the alert
messages for " Lost Failover communications with mate on interface 7"
and after i connetced on the pix and i 've seen this mistake.
I attached the show failover and show interface :
-------------------------SHOW
FAILOVER----------------------------------------
Failover On
Cable status: Normal
Reconnect timeout 0:00:00
Poll frequency 15 seconds
This host: Primary - Active
Active time: 23160 (sec)
Interface DMZ-slot:7 (192.168.10.9): Normal
Interface DMZ-slot:6 (192.168.10.13): Normal
Interface DMZ-slot:5 (192.168.10.17): Normal
Interface DMZ-slot:4 (192.168.10.1): Normal
Interface DMZ-slot:3 (192.168.10.5): Normal
Interface inside (X.X.X.X): Normal
Interface outside (X.X.X.X): Normal
Interface DMZ-Slot:2 (X.X.X.X): Normal
Other host: Secondary - Standby
Active time: 0 (sec)
Interface DMZ-slot:7 (192.168.10.10): Normal
Interface DMZ-slot:6 (192.168.10.14): Normal
Interface DMZ-slot:5 (192.168.10.18): Normal
Interface DMZ-slot:4 (192.168.10.2): Normal
Interface DMZ-slot:3 (192.168.10.6): Normal
Interface inside (X.X.X.X): Normal
Interface outside (X.X.X.X): Normal
Interface DMZ-Slot:2 (X.X.X.X): Normal
Stateful Failover Logical Update Statistics
Link : DMZ-slot:4
Stateful Obj xmit xerr rcv rerr
General 4728402 8463 36978 0
sys cmd 3119 0 3114 0
up time 2 0 2 0
xlate 1045 0 351 0
tcp conn 4724236 0 33511 71
udp conn 0 0 0 0
ARP tbl 0 0 0 0
RIP Tbl 0 0 0 0
Logical Update Queue Information
Cur Max Total
Recv Q: 0 128 36978
Xmit Q: 0 419 4738791
-----------------------------SHOW
INTERFACE-------------------------------
interface ethernet5 "DMZ-slot:7" is up, line protocol is up
Hardware is i82558 ethernet, address is 00e0.b604.4866
IP address 192.168.10.9, subnet mask 255.255.255.252
MTU 1500 bytes, BW 100000 Kbit full duplex
1498 packets input, 92852 bytes, 0 no buffer
Received 2 broadcasts, 0 runts, 0 giants
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
1538 packets output, 105116 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets
0 babbles, 0 late collisions, 0 deferred
0 lost carrier, 0 no carrier
input queue (curr/max blocks): hardware (128/128) software (0/2)
output queue (curr/max blocks): hardware (0/10) software (0/9)
------------------------------------------------------------------------
--------------------------------
Is it possible an attack ?
THANKS FOR YOUR COLLABORATION.
CIAO
Roberto P.
-----Messaggio originale-----
Da: Zhang, Anchi [mailto:AZhang@reliant.com]
Inviato: luned́ 25 marzo 2002 16.47
A: Roberto Paoletti; cisco-nsp@puck.nether.net
Oggetto: RE: PIX Firewall serie 535
How is the interface 7 on your secondary connected to that of your
primary? Via a crossover cable, a switch, or a hub?
What is interface 7 for? Your outside interface?
Did the primary reboot?
"show failover" and "show interface" output would be helpful.
Anchi
-----Original Message-----
From: Roberto Paoletti [mailto:roberto.paoletti@mail.wind.it]
Sent: Monday, March 25, 2002 9:21 AM
To: cisco-nsp@puck.nether.net
Subject: PIX Firewall serie 535
Hi ,
i' ve a problem with the pix 535.
Sometimes (2 times) the secondary pix (license failover) with status
Standby , losts comunication on interface X and goes in Testing.
The interface X is back -to-back with the primary pix with status Active
:
%PIX-1-105005: (Secondary) Lost Failover communications with mate on
interface 7
After the secondary monitoring the others interfaces :
%PIX-1-105003: (Secondary) Monitoring on interface 3 waiting
%PIX-1-105003: (Secondary) Monitoring on interface 6 waiting
%PIX-1-105003: (Secondary) Monitoring on interface 2 waiting
%PIX-1-105003: (Secondary) Monitoring on interface 5 waiting
%PIX-1-105003: (Secondary) Monitoring on interface 0 waiting
%PIX-1-105003: (Secondary) Monitoring on interface 4 waiting
%PIX-1-105003: (Secondary) Monitoring on interface 1 waiting
Why does the pix work so ?
Which is or are problem/s ?
I thought the connectivity (network), but the interface is back-to-back.
I thought the cable, it doesn't work.....but i change the cable.....
I've seen the logs and i didn't find nothing interesting .
Can anyone help me ?
Thanks in advance,
Roberto Paoletti
Operations Server Farm & Networking
Network Security & AAA
------------------------------------------------------------------
Wind Telecomunicazioni S.p.A. -
<file:///D:/Documents%20and%20Settings/Administrator.RPAOLETTI-NT/Dati%2
0applicazioni/Microsoft/Signatures/www.wind.it> www.wind.it
Internet & Multimedia - Fixed Portal
via Lorenteggio, 257
20152 Milano
Tel: +39-02-3011 4166
Cell:+39-3294206077
E-mail:roberto.paoletti@mail.wind.it