Re: [nsp] Input and CRC errors on PA-2T3

From: Adam Korab (adam@inebraska.com)
Date: Thu Apr 04 2002 - 02:03:08 EST


On Thu, Apr 04, 2002 at 09:34:00AM +0800, Angelo De Guzman wrote:
> Hi,
> I hava a PA-2T3 connection going to a remote site. When I try to do
> extended ping I dont get any errors. I even tried to increase the bit pattern,
> increase the byte size and still I dont get input errors and frame errors. Once
> I enable BGP peering to the remote site, then the input and CRC errors keeps on
> incrementing. The same number ccan be seen on the input and CRC erros. Anyone
> encountered this problem before?

Check the signal level coming in from the telco. I've seen this sort of
thing before on a paticularly troublesome DS3, and it turned out the
front-end receiver was being overloaded. (The PA evetually burned out.)

--Adam

-- 