Re: [nsp] connected flaps?

From: Jon Lewis (jlewis@inorganic5.fdt.net)
Date: Fri Aug 14 1998 - 12:54:59 EDT


On Fri, 14 Aug 1998 bmanning@ISI.EDU wrote:

> sh in f2/0
> FastEthernet2/0 is up, line protocol is up
> Hardware is cyBus FastEthernet Interface, address is 0060.5c61.c240 (bia 0060.5c61.c240)
> Internet address is 198.32.146.11/24
> Full-duplex, 100Mb/s, 100BaseTX/FX
> Last clearing of "show interface" counters never
> 3875384 input errors, 3875384 CRC, 1908734 frame, 0 overrun, 0 ignored, 0 abort
> 0 output errors, 0 collisions, 1 interface resets

I'd say that's "interesting". Is this just a short fast ethernet
connection into a switch...or something more unusual? Look at all those
CRC errors. I'd clear co f2/0 and see how fast the CRC's are happening.

------------------------------------------------------------------
 Jon Lewis <jlewis@fdt.net> | Spammers will be winnuked or
 Network Administrator | drawn and quartered...whichever
 Florida Digital Turnpike | is more convenient.
______http://inorganic5.fdt.net/~jlewis/pgp for PGP public key____



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:13 EDT