Re: [nsp] connected flaps?

From: bmanning@ISI.EDU
Date: Fri Aug 14 1998 - 13:25:06 EDT


> On Fri, 14 Aug 1998 bmanning@ISI.EDU wrote:
>
> > sh in f2/0
> > FastEthernet2/0 is up, line protocol is up
> > Hardware is cyBus FastEthernet Interface, address is 0060.5c61.c240 (bia 0060.5c61.c240)
> > Internet address is 198.32.146.11/24
> > Full-duplex, 100Mb/s, 100BaseTX/FX
> > Last clearing of "show interface" counters never
> > 3875384 input errors, 3875384 CRC, 1908734 frame, 0 overrun, 0 ignored, 0 abort
> > 0 output errors, 0 collisions, 1 interface resets
>
> I'd say that's "interesting". Is this just a short fast ethernet
> connection into a switch...or something more unusual? Look at all those
> CRC errors. I'd clear co f2/0 and see how fast the CRC's are happening.

It's a bit "unusual"... :)
I've cleared them and will check for correlation.. Thanks.

-- 
--bill