RE: [nsp] PA-A3 on 7206

From: Ming (mingf@HK.Super.NET)
Date: Fri Aug 28 1998 - 13:15:50 EDT


Hi,

I've tried to insert the PA-A3 card into another 7206 running 11.2(15)P,
but the same problem still came out.

Right now, I've tried 3 11.2 versions of IOS, and all failed to detect the
adaptor. Only the code 11.1(19)CC works properly for the card.

Any idea?

Regards,

Ming

On Fri, 28 Aug 1998, Christian Kratzer wrote:

> Him
>
> you require a 11.2 P relase for the 7206 to support nearly
> any port adapter.
>
> The most current would be 11.2(15)P. Make sure you have the 'P'
>
> Greetings
> Christian Kratzer
> Toplink
>
> --
> TopLink Internet Services GmbH info@toplink.net
> Christian Kratzer http://www.toplink.net/
> Phone: +49 7032 2701-0
> Fax: +49 7032 2701-19 FreeBSD spoken here!
>
>
> > -----Original Message-----
> > From: Ming [mailto:mingf@HK.Super.NET]
> > Sent: Freitag, 28. August 1998 12:10
> > To: cisco-nsp@iagnet.net
> > Subject: [nsp] PA-A3 on 7206
> >
> >
> >
> > Hi,
> >
> > I have a PA-A3 which is need to be installed on a cisco7206. The IOS
> > version is 11.2(11). I found that the router could not
> > recognize the PA-A3
> > card, which caused a insertion failure message. From
> > documentation, it is
> > said to be supported on IOS 11.1.19 or later.
> >
> > I have tried to insert the card into another 7206 running
> > 11.1(19)CC1, and
> > the router could detect the card withour any problem.
> >
> > I would like to ask which IOS code do I need to run in order to
> > support PA-A3 on 7206? If I need to run IOS 11.2, what can I do?
> >
> > Regards,
> >
> > Ming
> >
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:13 EDT