Hi!
I've the following problem:
I've an old Cisco 4000 with 16Mb RAM and a channelized E1 NMP.
This E1 has 3 actually 3 channel-groups of 4 timeslots each one.
Today, we tried to add a 4th channel-group and boooooom! Out of
memory... :-(
Here is the exact message (repeated several times until we deleted the
new
channel-group)
Jul 3 17:01:48 XXX 135: -Traceback= DB13C DC08A DC5CA 37430 3974C 36E92
36EF6 47722 47036 470D8 4715C 4DBC0 EBCE2 C907C C91E8
Jul 3 17:02:18 XXX 136: %SYS-2-MALLOCFAIL: Memory allocation of 80
bytes failed from 0xDC5C2, pool I/O, alignment 4
Jul 3 17:02:18 XXX 137: -Process= "Net Periodic", ipl= 4, pid= 25
Jul 3 17:02:18 XXX 138: -Traceback= DB13C DC08A DC5CA 37430 3974C 36E92
36EF6 47722 47036 470D8 4715C 4DBC0 EBCE2 C907C C91E8
Jul 3 17:02:48 XXX 139: %SYS-2-MALLOCFAIL: Memory allocation of 80
bytes failed from 0xDC5C2, pool I/O, alignment 4
Jul 3 17:02:48 XXX 140: -Process= "Net Periodic", ipl= 4, pid= 25
Jul 3 17:02:48 XXX 141: -Traceback= DB13C DC08A DC5CA 37430 3974C 36E92
36EF6 47722 47036 470D8 4715C 4DBC0 EBCE2 C907C C91E8
etc...
Could somebody give me more information? What can you recommand as
memory upgrade
etc... Help!
Here follows some usefull info about the router:
XXX#sh ver
Cisco Internetwork Operating System Software
IOS (tm) 4000 Software (C4000-P-M), Version 11.2(13), RELEASE SOFTWARE
(fc1)
Copyright (c) 1986-1998 by cisco Systems, Inc.
Compiled Tue 31-Mar-98 13:33 by tlane
Image text-base: 0x00012000, data-base: 0x00422674
ROM: System Bootstrap, Version 4.14(9), SOFTWARE
XXX uptime is 7 hours, 35 minutes
System restarted by reload
System image file is "c4000-p-mz.112-13.bin", booted via flash
cisco 4000 (68030) processor (revision 0xA0) with 16384K/1024K bytes of
memory.
Processor board ID 5012075
G.703/E1 software, Version 1.0.
Channelized E1, Version 1.0.
X.25 software, Version 2.0, NET2, BFE and GOSIP compliant.
Primary Rate ISDN software, Version 1.0.
2 Ethernet/IEEE 802.3 interface(s)
5 Serial network interface(s)
1 Channelized E1/PRI port(s)
128K bytes of non-volatile configuration memory.
4096K bytes of processor board System flash (Read/Write)
Configuration register is 0x2102
XXX#sh memory
Head Total(b) Used(b) Free(b) Lowest(b)
Largest(b)
Processor 490C24 11989980 926408 11063572 10924940
11043460
I/O 6000000 1048576 965560 83016 40
82748
SRAM 1000 65536 61104 4432 4368
4368
XXX#
Anyway, thanks for your help!
Xavier
-- Xavier Mertens ICQ: 8398489@work "Plug it in! Waowwwwww! http://www.bru-noc.net 12649924@home Let's continue with the next demo"