>Seeing a lot of line protocol bounces on T1's in log files:
>
>For example:
>
>Dec 10 02:48:27 e1-1.baltimore.mae-east.clark.net 111498:
>%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial2/5, changed state
>to down
>Dec 10 02:48:27 e1-1.baltimore.mae-east.clark.net 111499:
>%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial2/5, changed state
>to up
>
>
>
>
>Bounces up and down in < 1 second - logs only show it for one end of the
>T1 not the other.
>
>Not sure if this is real, false positives, etc..
>
>Anyone seen this before?
>
> Stb
Stephen,
I have seen this a LOT in teaching labs, typically in around 10.3/11.0. It
doesn't seem to hurt anything, but would not clear without a reboot.
Interestingly, this was on V.35 interfaces linked with DTE/DCE null cables,
so it was not a DSU/CSU issue.
Howard