> At 20:02 12/12/97 -0500, Stephen Balbach wrote:
>
> > full sh int:
> >
> > MTU 1500 bytes, BW 1536 Kbit, DLY 20000 usec, rely 255/255, load 4/255
> ^^^^^^^^^^^^
> Interesting that the link is nonetheless being seen as 100% reliable (over
> the last 5 minutes anyway).
Well, 100% in that the router hasn't logged any errors. If you ping
the upstream interface, do you observe any loss? (say 1000 small
packets.)
I haven't seen this behavior however, if neither side of the circuit
is showing errors (and I trust the CSU's error counters to give a more
accurate reading since they're technically monitoring at a different
level) then there is a good chance its an odditity with the code
release. First thing to make absolutely sure of is that the circuit is
clean since 9 times out of 10 when you see stuff like this in the logs
its going to indicate an error on the circuit.
----------------------------------------------------------------------
Wayne Bouchard GlobalCenter
web@primenet.com
Primenet Network Operations Internet Solutions for
(602) 416-6422 800-373-2499 x6422 Growing Businesses
FAX: (602) 416-9422
http://www.primenet.com http://www.globalcenter.net
----------------------------------------------------------------------
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:14 EDT