How can I predict if a particular router supports EOIR? Looks like the
bus might be rev1.0 ? My show diag is below. We're installing an AIP
card and need to predict the amount of outage time.
xxxxic01#term len 0
xxxxic01#sho diag
Slot 2:
Physical slot 2, ~physical slot 0xD, logical slot 2, CBus 0
Microcode Status 0x0
Master Enable, LED, WCS Loaded
Board is analyzed
EEPROM format version 1
EIP controller, HW rev 1.7, board revision D0
Serial number: 02721007 Part number: 73-0906-04
Test history: 0x00 RMA number: 00-00-00
Flags: cisco 7000 board; 7500 compatible
EEPROM contents (hex):
0x20: 01 00 01 07 00 29 84 EF 49 03 8A 04 00 00 00 00
0x30: 68 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Slot database information:
Flags: 0x4 Insertion time: 0x3EC (26w2d ago)
Slot 3:
Physical slot 3, ~physical slot 0xC, logical slot 3, CBus 0
Microcode Status 0x1
Master Enable, LED, WCS Loaded
Board is analyzed
EEPROM format version 1
HIP controller, HW rev 1.5, board revision D0
Serial number: 02915531 Part number: 81-0050-02
Test history: 0x00 RMA number: 00-00-00
Flags: cisco 7000 board; 7500 compatible
EEPROM contents (hex):
0x20: 01 03 01 05 00 2C 7C CB 51 00 32 02 00 00 00 00
0x30: 68 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Slot database information:
Flags: 0x4 Insertion time: 0x3EC (26w2d ago)
Slot 4:
Physical slot 4, ~physical slot 0xB, logical slot 4, CBus 0
Microcode Status 0xF
Master Enable, LED, WCS Loaded
Board is analyzed
EEPROM format version 1
HIP controller, HW rev 1.5, board revision D0
Serial number: 02585509 Part number: 81-0050-02
Test history: 0x00 RMA number: 00-00-00
Flags: cisco 7000 board; 7500 compatible
EEPROM contents (hex):
0x20: 01 03 01 05 00 27 73 A5 51 00 32 02 00 00 00 00
0x30: 68 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Slot database information:
Flags: 0x4 Insertion time: 0x3EC (26w2d ago)
Slot 5:
Physical slot 5, ~physical slot 0xA, logical slot 5, CBus 0
Microcode Status 0x1
Master Enable, LED, WCS Loaded
Board is analyzed
EEPROM format version 1
HIP controller, HW rev 1.5, board revision D0
Serial number: 02557364 Part number: 81-0050-02
Test history: 0x00 RMA number: 00-00-00
Flags: cisco 7000 board; 7500 compatible
EEPROM contents (hex):
0x20: 01 03 01 05 00 27 05 B4 51 00 32 02 00 00 00 00
0x30: 68 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Slot database information:
Flags: 0x4 Insertion time: 0x3EC (26w2d ago)
Slot 6:
EEPROM format version 1
Route/Switch Processor 2, HW rev 1.2, board revision B0
Serial number: 03347525 Part number: 73-1324-04
Test history: 0x00 RMA number: 00-00-00
Flags: cisco 7000 board; 7500 compatible
EEPROM contents (hex):
0x20: 01 0F 01 02 00 33 14 45 49 05 2C 04 00 00 00 00
0x30: 58 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Slot 9:
Physical slot 9, ~physical slot 0x6, logical slot 9, CBus 0
Microcode Status 0x0
Master Enable, LED, WCS Loaded
Board is analyzed
EEPROM format version 1
FSIP controller, HW rev 1.1, board revision C0
Serial number: 02533249 Part number: 73-1126-05
Test history: 0x00 RMA number: 00-00-00
Flags: cisco 7000 board; 7500 compatible
EEPROM contents (hex):
0x20: 01 07 01 01 00 26 A7 81 49 04 66 05 00 00 00 00
0x30: 60 00 00 00 FF 00 00 00 00 00 00 00 00 00 00 00
Slot database information:
Flags: 0x4 Insertion time: 0x3EC (26w2d ago)
Slot 10:
Physical slot 10, ~physical slot 0x5, logical slot 10, CBus 0
Microcode Status 0x0
Master Enable, LED, WCS Loaded
Board is analyzed
EEPROM format version 1
FSIP controller, HW rev 1.1, board revision C0
Serial number: 03502473 Part number: 73-1126-05
Test history: 0x00 RMA number: 00-00-00
Flags: cisco 7000 board; 7500 compatible
EEPROM contents (hex):
0x20: 01 07 01 01 00 35 71 89 49 04 66 05 00 00 00 00
0x30: 60 00 00 00 FF 00 00 00 00 00 00 00 00 00 00 00
Slot database information:
Flags: 0x4 Insertion time: 0x3EC (26w2d ago)
Slot 11:
Physical slot 11, ~physical slot 0x4, logical slot 11, CBus 0
Microcode Status 0x0
Master Enable, LED, WCS Loaded
Board is analyzed
EEPROM format version 1
FSIP controller, HW rev 1.1, board revision C0
Serial number: 02537931 Part number: 73-1126-05
Test history: 0x00 RMA number: 00-00-00
Flags: cisco 7000 board; 7500 compatible
EEPROM contents (hex):
0x20: 01 07 01 01 00 26 B9 CB 49 04 66 05 00 00 00 00
0x30: 60 00 00 00 FF 00 00 00 00 00 00 00 00 00 00 00
Slot database information:
Flags: 0x4 Insertion time: 0x3EC (26w2d ago)
Slot 31 (virtual):
EEPROM format version 1
Chassis Interface, HW rev 1.0, board revision B0
Serial number: 03122888 Part number: 73-1306-02
Test history: 0x00 RMA number: 00-00-00
Flags: cisco 7000 board
EEPROM contents (hex):
0x20: 01 10 01 00 00 2F A6 C8 49 05 1A 02 00 00 00 00
0x30: 58 00 00 00 FF 00 00 00 00 00 00 00 00 00 00 00
xxxxic01#quit
Thanks much,
--Ben Kirkpatrick
Data Products, Electric Lightwave, 360-816-3508
"Consciousness: that annoying time between naps."
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:14 EDT