[nsp] EOIR

From: Bremen Lee (bremenlee@attmail.com)
Date: Sun Dec 14 1997 - 23:46:45 EST


Hi,

My 7513 is running IOS 11.1(12)CA1 and got following message when I
insert a new Dual port Channelize
T1 card.

Dec 15 11:19:07 c7000 978: %OIR-6-INSCARD: Card inserted in slot 3,
interfaces administratively shut down
Dec 15 11:19:08 c7000 979: %OIR-6-NOEOIR: T1 2/0 hardware version 1.0
not capable of EOIR
Dec 15 11:19:08 c7000 980: %OIR-6-NOEOIR: T1 2/1 hardware version 1.0
not capable of EOIR
Dec 15 11:19:15 c7000 981: %CBUS-3-BADVC: MIP 2/0 got bad VC packet
Dec 15 11:19:15 c7000 982: 8F008035 00000002 00014441 0006A297 FFFF44E0
BDF1000A CF6B0000 00000000
Dec 15 11:19:24 c7000 983: %CONTROLLER-3-UPDOWN: Controller T1 2/0,
changed state to up
Dec 15 11:19:24 c7000 984: %CONTROLLER-3-UPDOWN: Controller T1 2/1,
changed state to up
Dec 15 11:19:24 c7000 985: %CBUS-3-CMDTIMEOUT: Cmd timed out, CCB
0x5800FF40, slot 2, cmd code 2
Dec 15 11:19:24 c7000 986: -Traceback= 601D4268 601D4A24 601DB6AC
601F5D10 60056428 601093BC 60109520 601191F0 601191DC
Dec 15 11:19:24 c7000 987: %CBUS-3-DAUGHTER_NO_RSP: Unit 2, daughter 0,
not responding (0x8010) - disabled
Dec 15 11:19:24 c7000 988: %CONTROLLER-2-CRASHED: Interface Processor in
slot 2 not responding (8010): shutting it down
Dec 15 11:19:24 c7000 989: -Traceback= 601F6A70 601F69EC 601F5D40
60056428 601093BC 60109520 601191F0 601191DC
Dec 15 11:19:24 c7000 990: %CONTROLLER-3-UPDOWN: Controller T1 2/0,
changed state to administratively down
Dec 15 11:19:24 c7000 991: %CONTROLLER-3-UPDOWN: Controller T1 2/1,
changed state to administratively down
Dec 15 11:19:24 c7000 992: %LINEPROTO-5-UPDOWN: Line protocol on
Interface Serial2/0:19, changed state to down
Dec 15 11:19:24 c7000 993: %LINEPROTO-5-UPDOWN: Line protocol on
Interface Serial2/0:17, changed state to down

In fact what is EOIR and how can I disable it?

Cheers,

Bremen