Thanks Barry. Thats exactly what im looking for.
Stb
On Thu, 15 Jan 1998, Barry L. Bruins wrote:
> The values in the locIfInBitsSec are the 5 minute average values.
> Check out: ftp://www.cisco.com/pub/mibs/v1/OLD-CISCO-INTERFACES-MIB.my
>
> Barry
> >
> >
> > Currently developing a system to track usage stats on cisco interfaces in
> > order to bill based on usage (burstable service).
> >
> > Pulling the IfOctets of total bytes, the stats seems to mysteriously reset
> > to 0 on occasion. No reboots, etc.. throws the count off and makes one
> > wonder how reliable the 'total bytes' stats are.
> >
> > What is the best method of getting reliable cisco usage stats, on a 5
> > minute basis, over a long period. Prefer SNMP because of the low resource
> > overhead vs. an expect script. Unable to find a SNMP variable that shows
> > the 5-minute average as seen in 'sh int'.
> >
> > Stb
> >
> >
>
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:14 EDT