> Are you using a real "CT1" CSU (DL 303 comes to mind). If I recall, the
> CT1 cards have inbuilt DSU so using a CSU/DSU messes with it's mind.
>
> Also, have you configured proper timeslots? "channel-group 0 timeslots
> 1-24 speed 64" for t1? If you're looking at a loop on the entire DS1 the
> speed may not make a difference.
>
> FWIW ;)
>
> Peter
The 'speed 64' was what I was missing.
Thanks very much...
Avi
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:16 EDT