Re: [nsp] 3640 CT1 Problem

From: Avi Freedman (freedman@netaxs.com)
Date: Mon Mar 30 1998 - 23:29:27 EST


> Are you using a real "CT1" CSU (DL 303 comes to mind). If I recall, the
> CT1 cards have inbuilt DSU so using a CSU/DSU messes with it's mind.
>
> Also, have you configured proper timeslots? "channel-group 0 timeslots
> 1-24 speed 64" for t1? If you're looking at a loop on the entire DS1 the
> speed may not make a difference.
>
> FWIW ;)
>
> Peter

The 'speed 64' was what I was missing.
Thanks very much...

Avi