Try using numbered ACL rather than named one.
I believe there are some weird issues with named
ACL's in some situations.
-----Original Message-----
From: Zhang, Anchi [mailto:AZhang@reliant.com]
Sent: Tuesday, October 23, 2001 18:17
To: 'Cisco-Nsp (E-mail)
Subject: [nsp] frac t3 down when access-list changed
Greetings,
Has anybody ever seen the problem in which a modification to the
access-list already applied to a serial interface may bring down the
interface and a shut/no shut would bring it back? It is happening to
our 7204 with a frac T3 connecting to UUNet running
IOS (tm) 7200 Software (C7200-IK9O3S-M), Version 12.2(3), RELEASE
SOFTWARE (fc1)
and the access-list is applied to the interface as
interface Serial1/0.500 point-to-point
ip access-group INGRESS in
Anchi