I don't see the bug ID, please provide that.
The bug states that if you upgrad efrom 12.0(15)S2 to 12.0(16.6)S then you will
see this problem but you say you are running 12.(15)S1, so this bug does not
apply.
Ususally, the latest 12.0S IOS release is the greatest because it has the most
bug fixes.
Alex Yeung
>
> Hi Mr.cisco techs
>
> My partner Boris found something on cisco bug nevigator page as
> below,it shows some pontenial bugs
> I don't know it's link with my problem,but regional cisco tech manger
> suggested us upgrade to 12.0.18s1~
> And my bandwidth is full mode for reply to chris
>
> What do you think ? my ios and bootimage ver are 12.0.15s1
>
> Thanks all
> Micky
>
> Bug navigator show from cisco
>
> MBUS-0-DOWNREV, MBUS-2-DNLDFAIL after upgrade cause FIB-3-FIBDISABLE
> Product c12000 Model
> Component gsr-mbus Duplicate of
> Severity 1 Status R
> Version Found 12.0(16.6)S3.0516 Fixed-in Version 12.0(17)ST01
> 12.0(18.5)S 12.0(17.6)ST03 12.0(18.5)ST 12.0(18)S01
> Release Notes
>
> After an upgrade to 12.0(16.6)S3.0516 from an earlier IOS version based
> on 12.0(15)S2, some linecards might have problems to boot :
>
> %MBUS-0-DOWNREV: MBUS agent in slot 1 running from ROM
> %MBUS-2-DNLDFAIL: MBUS Agent RAM download to slot 1
>
> and end up in FIB disable state (dCEF not running) after 6 minutes for the
> linecards not up.
>
> %FIB-3-FIBDISABLE: Fatal error, slot 7: No window message, LC to RP IPC is
> non-
> operational
>
> Workaround: a "microcode reload" or complete reload seems to fix the problem
> sometimes.
>
>
>
>
>
> ----- Original Message -----
> From: "Alex Yeung" <alyeung@cisco.com>
> To: "micky" <micky@apol.com.tw>
> Cc: <cisco-nsp@puck.nether.net>; <boris@apol.com.tw>; "Desmarais, Jonathan"
> <JDesmarais@colt-telecom.com>
> Sent: Tuesday, October 30, 2001 2:06 AM
> Subject: RE: [nsp] Cisco GSR12012 support 3port GE line card ?
>
>
> > Can you provide the output of the following commands:
> >
> > Look at the outputs of the following command:
> > sh diag <slot#>
> > sh gsr slot <slot#>
> > sh controller fia, look for crc16 errors
> >
> > Which IOS are you running on the two GSRs?
> >
> > Alex Yeung
> >
> > > -----Original Message-----
> > > From: micky [mailto:micky@apol.com.tw]
> > > Sent: Sunday, October 28, 2001 5:13 PM
> > > To: Alex Yeung
> > > Cc: cisco-nsp@puck.nether.net; boris@apol.com.tw; Desmarais, Jonathan
> > > Subject: Re: [nsp] Cisco GSR12012 support 3port GE line card ?
> > >
> > >
> > > Hi Alex Yeung
> > >
> > > I have tried different slot on GSR 12012,but still didn't work
> > > But I inserted into GSR model 12016 and it worked,that's very
> tricky
> > > and ridiculous
> > > The two GSRs(12012 and 12016) are running the same IOS version
> > > Could you give me more tips or clues ?
> > >
> > > Special thanks
> > > Micky
> > > ----- Original Message -----
> > > From: "Alex Yeung" <alyeung@cisco.com>
> > > To: "micky" <micky@apol.com.tw>; "Desmarais, Jonathan"
> > > <JDesmarais@colt-telecom.com>
> > > Cc: <cisco-nsp@puck.nether.net>; <boris@apol.com.tw>
> > > Sent: Monday, October 29, 2001 8:23 AM
> > > Subject: RE: [nsp] Cisco GSR12012 support 3port GE line card ?
> > >
> > >
> > > > >
> > > > > Hi Jon
> > > > >
> > > > > It's strange
> > > > > I have used the version on GSR 12016 for a long time,that's
> > > fine,no
> > > > > any problem
> > > > > What's difference between 12012 and 12016 ?
> > > >
> > > > 12012 is a 12-slot GSR, 12016 is a 16-slot GSR.
> > > >
> > > > >
> > > > >
> > > > >
> > > > > > You need 12.015S2 at least.
> > > >
> > > > 3xport GE is supported from 12.0(11)S3.
> > > >
> > > > > >
> > > > > > I have the same issue, try using 12.016S(thelatest) it works well.
> > > > > >
> > > >
> > > > The latest is 12.0(19)S for the GSR.
> > > >
> > > > Alex Yeung
> > > >
> > > >
> > > > > > Cheers
> > > > > > Jon
> > > > > >
> > > > > > -----Original Message-----
> > > > > > From: micky [mailto:micky@apol.com.tw]
> > > > > > Sent: 26 October 2001 11:24
> > > > > > To: cisco-nsp@puck.nether.net
> > > > > > Subject: [nsp] Cisco GSR12012 support 3port GE line card ?
> > > > > >
> > > > > >
> > > > > > Hi Mr.nsp
> > > > > >
> > > > > > My GSR12012 is running IOS ver 12.0.15s1
> > > > > > When I finished inserting the line card,I found card was
> detected
> > > by
> > > > > IOS
> > > > > > But the front panel led showed "up" ,not "run"
> > > > > > It's very strange,this caused GE port to be down
> > > > > >
> > > > > > Anyone about this condition ?
> > > > > >
> > > > > > Thanks
> > > > > > Have a nice weekend
> > > > > > Micky
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > **********************************************************************
> > > > > > COLT Telecommunications
> > > > > > Registered in England No. 2452736
> > > > > > Registered Office: Bishopsgate Court, 4 Norton Folgate,
> > > London E1 6DQ
> > > > > > Tel. 020 7390 3900
> > > > > >
> > > > > > This message is subject to and does not create or vary any
> > > contractual
> > > > > > relationship between COLT Telecommunications, its subsidiaries or
> > > > > > affiliates ("COLT") and you. Internet communications are not
> secure
> > > > > > and therefore COLT does not accept legal responsibility for the
> > > > > > contents of this message. Any view or opinions expressed
> > > are those of
> > > > > > the author. The message is intended for the addressee only and its
> > > > > > contents and any attached files are strictly confidential.
> > > If you have
> > > > > > received it in error, please telephone the number above. Thank
> you.
> > > > > >
> > > > > >
> > > > > >
> > > **********************************************************************
> > > > >
> > > > >
> > >
> > >
>
>
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:21 EDT