I would recommend 12.0(19)S
That should fix most of your problems.
- Jared
On Wed, Oct 31, 2001 at 09:04:19AM +0800, micky wrote:
> Hi Mr.cisco techs
>
> My partner Boris found something on cisco bug nevigator page as
> below,it shows some pontenial bugs
> I don't know it's link with my problem,but regional cisco tech manger
> suggested us upgrade to 12.0.18s1~
> And my bandwidth is full mode for reply to chris
>
> What do you think ? my ios and bootimage ver are 12.0.15s1
>
> Thanks all
> Micky
>
> Bug navigator show from cisco
>
> MBUS-0-DOWNREV, MBUS-2-DNLDFAIL after upgrade cause FIB-3-FIBDISABLE
> Product c12000 Model
> Component gsr-mbus Duplicate of
> Severity 1 Status R
> Version Found 12.0(16.6)S3.0516 Fixed-in Version 12.0(17)ST01
> 12.0(18.5)S 12.0(17.6)ST03 12.0(18.5)ST 12.0(18)S01
> Release Notes
>
> After an upgrade to 12.0(16.6)S3.0516 from an earlier IOS version based
> on 12.0(15)S2, some linecards might have problems to boot :
>
> %MBUS-0-DOWNREV: MBUS agent in slot 1 running from ROM
> %MBUS-2-DNLDFAIL: MBUS Agent RAM download to slot 1
>
> and end up in FIB disable state (dCEF not running) after 6 minutes for the
> linecards not up.
>
> %FIB-3-FIBDISABLE: Fatal error, slot 7: No window message, LC to RP IPC is
> non-
> operational
>
> Workaround: a "microcode reload" or complete reload seems to fix the problem
> sometimes.
>
>
>
>
>
> ----- Original Message -----
> From: "Alex Yeung" <alyeung@cisco.com>
> To: "micky" <micky@apol.com.tw>
> Cc: <cisco-nsp@puck.nether.net>; <boris@apol.com.tw>; "Desmarais, Jonathan"
> <JDesmarais@colt-telecom.com>
> Sent: Tuesday, October 30, 2001 2:06 AM
> Subject: RE: [nsp] Cisco GSR12012 support 3port GE line card ?
>
>
> > Can you provide the output of the following commands:
> >
> > Look at the outputs of the following command:
> > sh diag <slot#>
> > sh gsr slot <slot#>
> > sh controller fia, look for crc16 errors
> >
> > Which IOS are you running on the two GSRs?
> >
> > Alex Yeung
> >
> > > -----Original Message-----
> > > From: micky [mailto:micky@apol.com.tw]
> > > Sent: Sunday, October 28, 2001 5:13 PM
> > > To: Alex Yeung
> > > Cc: cisco-nsp@puck.nether.net; boris@apol.com.tw; Desmarais, Jonathan
> > > Subject: Re: [nsp] Cisco GSR12012 support 3port GE line card ?
> > >
> > >
> > > Hi Alex Yeung
> > >
> > > I have tried different slot on GSR 12012,but still didn't work
> > > But I inserted into GSR model 12016 and it worked,that's very
> tricky
> > > and ridiculous
> > > The two GSRs(12012 and 12016) are running the same IOS version
> > > Could you give me more tips or clues ?
> > >
> > > Special thanks
> > > Micky
> > > ----- Original Message -----
> > > From: "Alex Yeung" <alyeung@cisco.com>
> > > To: "micky" <micky@apol.com.tw>; "Desmarais, Jonathan"
> > > <JDesmarais@colt-telecom.com>
> > > Cc: <cisco-nsp@puck.nether.net>; <boris@apol.com.tw>
> > > Sent: Monday, October 29, 2001 8:23 AM
> > > Subject: RE: [nsp] Cisco GSR12012 support 3port GE line card ?
> > >
> > >
> > > > >
> > > > > Hi Jon
> > > > >
> > > > > It's strange
> > > > > I have used the version on GSR 12016 for a long time,that's
> > > fine,no
> > > > > any problem
> > > > > What's difference between 12012 and 12016 ?
> > > >
> > > > 12012 is a 12-slot GSR, 12016 is a 16-slot GSR.
> > > >
> > > > >
> > > > >
> > > > >
> > > > > > You need 12.015S2 at least.
> > > >
> > > > 3xport GE is supported from 12.0(11)S3.
> > > >
> > > > > >
> > > > > > I have the same issue, try using 12.016S(thelatest) it works well.
> > > > > >
> > > >
> > > > The latest is 12.0(19)S for the GSR.
> > > >
> > > > Alex Yeung
> > > >
> > > >
> > > > > > Cheers
> > > > > > Jon
> > > > > >
> > > > > > -----Original Message-----
> > > > > > From: micky [mailto:micky@apol.com.tw]
> > > > > > Sent: 26 October 2001 11:24
> > > > > > To: cisco-nsp@puck.nether.net
> > > > > > Subject: [nsp] Cisco GSR12012 support 3port GE line card ?
> > > > > >
> > > > > >
> > > > > > Hi Mr.nsp
> > > > > >
> > > > > > My GSR12012 is running IOS ver 12.0.15s1
> > > > > > When I finished inserting the line card,I found card was
> detected
> > > by
> > > > > IOS
> > > > > > But the front panel led showed "up" ,not "run"
> > > > > > It's very strange,this caused GE port to be down
> > > > > >
> > > > > > Anyone about this condition ?
> > > > > >
> > > > > > Thanks
> > > > > > Have a nice weekend
> > > > > > Micky
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > **********************************************************************
> > > > > > COLT Telecommunications
> > > > > > Registered in England No. 2452736
> > > > > > Registered Office: Bishopsgate Court, 4 Norton Folgate,
> > > London E1 6DQ
> > > > > > Tel. 020 7390 3900
> > > > > >
> > > > > > This message is subject to and does not create or vary any
> > > contractual
> > > > > > relationship between COLT Telecommunications, its subsidiaries or
> > > > > > affiliates ("COLT") and you. Internet communications are not
> secure
> > > > > > and therefore COLT does not accept legal responsibility for the
> > > > > > contents of this message. Any view or opinions expressed
> > > are those of
> > > > > > the author. The message is intended for the addressee only and its
> > > > > > contents and any attached files are strictly confidential.
> > > If you have
> > > > > > received it in error, please telephone the number above. Thank
> you.
> > > > > >
> > > > > >
> > > > > >
> > > **********************************************************************
> > > > >
> > > > >
> > >
> > >
-- Jared Mauch | pgp key available via finger from jared@puck.nether.net clue++; | http://puck.nether.net/~jared/ My statements are only mine.
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:21 EDT