Re: Has anyone run POS modules?

From: Simon Leinen (simon@limmat.switch.ch)
Date: Tue Mar 20 2001 - 15:33:09 EST


>>>>> "bvd" == Brent Van Dussen <vandusb@attens.com> writes:
> Are your cards the advanced "NPA" cards or just the standard ones?

How do I tell? :-)
We have the cards since last November.

> We had an issue with our standard OC-48 cards that would require the
> card to be reloaded every couple of hours in order to maintain
> connectivity. Once we replaced with NPA cards everything worked
> great.

> Similar scenario except there was a GSR 12012 on one end, and a
> Nortel Optera DWDM ring running SONET in the middle.

I think the SDH gear we connect to is also from Nortel.

-- 
Simon.



This archive was generated by hypermail 2b29 : Mon Aug 04 2003 - 04:10:06 EDT