Re: [j-nsp] ISIS metric

From: HHH (jnciecert@yahoo.com)
Date: Tue Apr 09 2002 - 16:46:47 EDT


Depends...yes it generates both, but to use the wide metric values, you have
to define the wide-metrics-only to generete the values greater than 63.
This only needs to be enabled on the source, as they are understood
throughout the level as both TLV's(narrow and wide) are flooded.

----- Original Message -----
From: "Przemyslaw Karwasiecki" <karwas@ifxcorp.com>
To: <juniper-nsp@puck.nether.net>
Sent: Tuesday, April 09, 2002 4:37 PM
Subject: [j-nsp] ISIS metric

>
> All,
>
> simple question:
>
> It looks like ISIS enabled on interface automatically
> supports both metric styles (narrow and wide).
> Is it correct observation, or there is some knob
> I need to set to make sure.....
>
> Thanks,
>
> Przemek
>

_________________________________________________________
Do You Yahoo!?
Get your free @yahoo.com address at http://mail.yahoo.com