On Wed, Jan 09, 2002 at 11:36:47AM -0000, Luis Garrido wrote:
>
> Hello,
>
> We have a juniper M10 and the management is in-band, As we donīt have any
> equipment connected to the ethernet port mgmt of the juniper we have a
> critical alarm in the leds of the craft terminal. We donīt want this alarm
> since if another critical alarm appears we will not note that with the leds
> in the craft terminal.
set interface fxp0 disable
commit
Or put a RJ45 plug in there where you loop pin 1 to pin 3 and
pin 2 to pin 6, then the port will have link.
/Jesper
-- Jesper Skriver, jesper(at)skriver(dot)dk - CCIE #5456 Work: Network manager @ AS3292 (Tele Danmark DataNetworks) Private: FreeBSD committer @ AS2109 (A much smaller network ;-)One Unix to rule them all, One Resolver to find them, One IP to bring them all and in the zone to bind them.