Re: [j-nsp] ATM PVC traffic statistics via SNMP

From: Doug McPherson (dougm@ixen.com)
Date: Sat Mar 03 2001 - 12:11:22 EST


Oops. Sorry. My bad.
/doug
.

> I m not trying to poll traffic from sub-interfaces, i trying to get
in/outOctets from individual PVC within that sub-interfaces. the one that u
mentioned is just the total traffic from a bunch of PVCs.
>
> If u look at the config below, i would like the INDIVIDUAL in/outOctets
from PVC 0.65 and 0.66 SEPARATELY. Note that it a point-to-multipoint
config.
>
> Benny
>
> unit 0 {
> encapsulation atm-snap;
> multipoint;
> family inet {
> address 192.168.14.1/24 {
> multipoint-destination 192.168.14.2 {
> vci 0.65;
> shaping {
> vbr peak 4500000 sustained 3500000 burst 64;
> }
> inverse-arp;
> }
> multipoint-destination 192.168.14.3 {
> vci 0.66;
> shaping {
> vbr peak 4500000 sustained 3500000 burst 64;
> }
> inverse-arp;
> }
> }
> }
> }
>
> On Sat, Mar 03, 2001 at 10:05:55AM -0500, Doug McPherson wrote:
> |
> | > I would like to poll for InOctets/OutOctets on each individual PVCs
> | created with multipoint-destination
> | > on my ATM interfaces via SNMP just like what i did on my CISCO boxes
using
> | the following
> | > mibs, ftp://ftp.cisco.com/pub/mibs/v2/CISCO-AAL5-MIB.my. Does juniper
> | have the same
> | > thing as what CISCO boxes have? This is essential for billing
purposes.
> |
> | On Juniper boxes, the ATM sub-interfaces should get their own ifIndex ID
and
> | will return in/outOctets just like a regular interface. You don't need
to
> | use any ATM mibs to collect -- just standard interfaces MIB.
> | We collect per-pvc utilzation this way.
> |
> | /doug
> | --
> | Doug McPherson NaviPath, Inc. - a CMGI Company
> | Director, Network Management 800 Federal Street
> | mailto:dougm@navipath.com Andover, MA 01810
> | phone 978-933-6339 Fax: 978-933-6201
>
>



This archive was generated by hypermail 2b29 : Mon Aug 05 2002 - 10:42:40 EDT