monitor file dcd
Thu, Mar 08, 2001 at 03:04:18AM -0000, Raj Jakkampudi:
> Thanks for the response. I looked in the manual and see no details about
> what would be logged except that traceoptions can't be sent to a file and
> must be looked at through the syslog. I think this command only shows me
> physical link level information and not PPP encapsulation/negotiation
> information. For a t3, here is the config that I've used:
>
> t3-2/0/1 {
> traceoptions {
> flag all;
> }
> mtu 1504;
> encapsulation ppp;
> unit 0 {
> family inet {
> address 1.1.1.10/30;
> }
> }
> }
>
> thanks,
> /Raj
>
> P.S. Is this an appropriate question for this forum?
>
>
> >From: john heasley <heas@shrubbery.net>
> >To: Raj Jakkampudi <raj_jakkampudi1@hotmail.com>
> >CC: juniper-nsp@puck.nether.net
> >Subject: Re: [j-nsp] Debug of PPP on POS card
> >Date: Wed, 7 Mar 2001 15:32:41 -0800
> >
> >Wed, Mar 07, 2001 at 09:00:20PM -0000, Raj Jakkampudi:
> > > How do I enable the Cisco equivalent of "debug ppp all" on the M40?
> > >
> > > thanks,
> > > /Raj
> > > _________________________________________________________________
> > > Get your FREE download of MSN Explorer at http://explorer.msn.com
> >
> >see traceoptions.
>
> _________________________________________________________________
> Get your FREE download of MSN Explorer at http://explorer.msn.com
This archive was generated by hypermail 2b29 : Mon Aug 05 2002 - 10:42:40 EDT