Re: [j-nsp] Tunnel PIC

From: Greg Ketell (gketell@juniper.net)
Date: Fri Apr 06 2001 - 14:43:59 EDT


I'm not positive. I think not, though.

Although that is done at the FPC level and not the PIC level so it is
possible that it is done. If you are a customer you can send the question
to support@juniper.net and get the real answer.

GK

At 08:38 PM 4/6/2001 +0200, Robert Kiessling wrote:
>Greg Ketell writes:
> > And, as Avi pointed out, it is good for up to ~1Gb of tunnel encap/decap
> > per Tunnel PIC with no performance hit and you can have more than one
> > Tunnel PIC per chassis.
>
>Does it do fragmentation and reassembly so that you can preserve the
>MTU?
>
>Robert



This archive was generated by hypermail 2b29 : Mon Aug 05 2002 - 10:42:42 EDT