Frame-relay encapsulation is for a typical frame-relay connection - per RFC
- 1490.
Frame-relay CCC encapsulation is the same as standard frame-relay for DLCIs
0 through 511. However, DLCIs 512 through 1022 are used for the Circuit
Cross Connect feature. The CCC feature allows you to tunnel frame-relay (or
other layer-2) PDUs via an MPLS LSP.
I hope this helps.
/cf
-----Original Message-----
From: sipitung [mailto:sipitung@ekilat.com]
Sent: Thursday, April 26, 2001 10:35 AM
To: Juniper-Nsp
Subject: [j-nsp] frame-relay ccc
Hi group,
Is there anyone have idea a different between frame-relay and frame-relay
ccc in Juniper Box ?
And in what situation we should use frame-relay ccc ?
Any helps, suggests, comments will be appreciated.
Thanks
sipitung