That's not it Mark - the gent is asking about the enviormental problems he
is encounterring not about bus over subscription... the part of the log
that he is relaying is:
00:00:52: %UBR7200-0-TEMPHIGH: measured at 21C/69F is too
high: shutdown temperature 0C/32F
00:00:52: %ENVM-0-SHUT: Environmental Monitor initiated
shutdown
The rest is normal start up chatter.
Tejal - you are getting a high temp warning - the reason it is shutting
down is that you shutdown temp is incorrectly set to '0C/32F' (which is
freezing). The auto-shutdown is a safety to protect the box from damage
in high temperature envirments.
I know that CISCO released a slew of 12000's with faulty temperature
settings... For more info ou can look at:
http://www.cisco.com/warp/public/770/fn13107.shtml
On Jan 31, 2002 Mark Pace Balzan spake:
> The first line from you output shows you have exceeded bandwidth points in
> your slots.
>
> the 7206 requires that you calculate the points used by interfaces you use
> in which slots.
>
> You cannot put any amount of interfaces into any slot and expect it to work
> well.
> They have to be balanced across the two busses
>
> Search cisco's site for the details of bandwidth points and which interfaces
> to use in which slots and in which order
>
>
>
> Mark
>
>
>
> ----- Original Message -----
> From: "Tejal Shah" <tejal.shah@surat.iqara.net>
> To: <cisco-nsp@puck.nether.net>
> Sent: Thursday, January 31, 2002 1:52 PM
> Subject: [nsp] Environmental Monitor initiated shutdown on UBR7246VXR
>
>
> Hi all,
>
> I am getting following error when i reboot my ubr7246VXR
> CMTS with NPE-400.
>
> ========================================================
> 00:00:52: %SYS-3-LOGGER_FLUSHING: System pausing to ensure
> console debugging output.
>
> 00:00:06: %UBR7200-3-CONFIG: Exceeds 600 bandwidth points
> for slots 0, 1, 3 & 5
> 00:00:09: %LINK-3-UPDOWN: Interface FastEthernet0/0,
> changed state to up
> 00:00:09: %LINK-3-UPDOWN: Interface GigabitEthernet1/0,
> changed state to up
> 00:00:09: %LINK-3-UPDOWN: Interface Cable3/0, changed state
> to up
> 00:00:09: %LINK-3-UPDOWN: Interface Cable4/0, changed state
> to up
> 00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> FastEthernet0/0, changed state to up
> 00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> GigabitEthernet1/0, changed state to down
> 00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> Cable3/0, changed state to up
> 00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> Cable4/0, changed state to up
> 00:00:17: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> FastEthernet0/0, changed state to down
> 00:00:38: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> Cable3/0, changed state to down
> 00:00:38: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> Cable4/0, changed state to down
> 00:00:52: %UBR7200-0-TEMPHIGH: measured at 21C/69F is too
> high: shutdown temperature 0C/32F
> 00:00:52: %ENVM-0-SHUT: Environmental Monitor initiated
> shutdown
> Buffered messageó
> =========================================================
>
> Pl. help me out to resolve this problem.
>
> thanks in advance
> Tejal Shah
>
>
> Go To http://www.iqara.net
>
>
>
-- Rich Sena - ras@thick.net ThickNET Consulting "On the way to understanding; you understand, and forget."