On Fri, 4 Feb 2000 13:16:20 -0500
Chad Skidmore <cskidmore@avistacom.net> wrote:
> Brandon, we have a DS3 that is about the same distance. The circuit goes
> directly from one PAT3 to another and the times that we see are consistant
> 8ms-12ms when pinging from one router to the other.
>
someone else wrote
> We are getting avg. 25 msec on ping tests from the following link:
>
> pa-t3 <---- 600 mile DS3 (clear channel, full) ----> pa-t3
>
> Packet size does not affect our times.
>
> Can anyone give me their $ .02 on this ?? I am mainly concerned with the
> delay induced by the circuit itself, as we are able to tweak the router
> config on each end.
>
don't know the distance but here is a ds-3 from lon to ams:
2 fe-6-1-super-grover.LON.router.COLT.NET (212.74.64.201) 1.292 ms 0.886 ms 0.886 ms
3 s5-0-the-count.AMS.router.COLT.NET (212.74.64.194) 10.004 ms 9.988 ms 9.983 ms
Regards,
Neil.
-- Neil J. McRae C O L T I N T E R N E T neil@COLT.NET
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:09 EDT