Yes, you have to use 12.0S boot images. The oversized boot images was
release by mistake.
/pab
At 06:47 PM 6/15/00 -0700, Jay Stewart wrote:
>I am trying to load 12.0(7)T on my 7200, but the bootflash: partition is too
>small to accept it. (Image file: c7200-boot-mz.120-7.T.bin - 3,408,536.)
>Yes, I have deleted the other image and squeezed the partition, but it still
>doesn't fit. Does anyone have any ideas on how to get around this? Can I use
>the boot image c7200-boot-mz.120-9.bin and then have the system load from
>flash with c7200-js-mz.120-7.T.bin? Or will this cause conflicts?
>
>Thanks in advance for any advice/help anyone can give me on this issue.
>
>Jay Stewart
>Internet Network Engineer
>Olympia Networking Services - "The Northwest's Premier ISP"
>http://www.olywa.net
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:13 EDT