Re: [nsp] 12.0(12.??)S and PA-A3 problem

From: Mike Axelrod (maxelrod@digisle.net)
Date: Tue Oct 03 2000 - 12:38:01 EDT


> I've had a case open with the TAC for a while. Currently, the TAC
> is claiming that this problem and another PA-A3 problem I am having
> are being caused by my old revision PA-A3 (HW rev 1.0, Board rev
> A0, Part# 73-2430-03 if anyone is interested). I've been shipped
> a replacement and am waiting for a maintenance window to get it
> installed. The TAC, though, can't point to any DDTS or field notice
> that states there are problems with the revision PA-A3 that I have.

THERE is a field alret regarding new SAR in PA-A3 HW rev 2.0. Not sure if
it's related, but here it is :
http://www.cisco.com/warp/customer/770/fn2428_01121999.html

Mike Axelrod