Re: [nsp] 12.0.11S broken keepalive, 12.0.12S broken cAal5Vcc{In,Out}Octets

From: Jared Mauch (jared@puck.nether.net)
Date: Mon Dec 11 2000 - 14:14:33 EST


        I'm not having problems with 12.0(14)S on c7200 based equipment.

        - jared

On Mon, Dec 11, 2000 at 11:33:01AM +0100, Christian Kratzer wrote:
> Hi,
>
> we have several 7206VXR with mixtures of PA-8T, PA-A1, PA-E3, PA-FE-TX
> and are currently running c7200-p-mz.120-11.S.bin in an isp environment.
>
> Because of some problems I would like to update to a later 12.0.x S where X>12
>
> 1. We have a current problem wuith 12.0.11S that serials (cisco hdlc) on the
> PA-8T don't seem to go up/down when keepalives are lost. They keep toggling
> between up/up and up/down which totally defeates the purpose of keepalives.
>
> I have heard rumors that this would be fixed in later 12.0.11S but could
> not find anything on the web. Has anybody got a bug id for this ????
>
> 2. We tried updating to 12.0.12S but found the ATM mibs to be broken there. We
> poll atm pvc's for cAal5VccInOctets and cAal5VccOutOctets for accounting
> and stats purposes which didn't work with 12.0.12S.
>
> Can anybody confirm cAal5VccInOctets,cAal5VccOutOctets work with a later
> 12.0.x S on a 7206 ????
>
> Is there perhaps a bugid for this somewhere ???
>
> Greetings
> Christian Kratzer
> Toplink
>
> --
> TopLink Internet Services GmbH ck@171.2.195.in-addr.arpa
> Christian Kratzer http://www.toplink.net/
> Phone: +49 7032 2701-0
> Fax: +49 7032 2701-19 FreeBSD spoken here!

-- 
Jared Mauch  | pgp key available via finger from jared@puck.nether.net
clue++;      | http://puck.nether.net/~jared/  My statements are only mine.
END OF LINE  | Manager of IP networks built within my own home