Re: problem with point-to-point T1

From: Deepak Jain (deepak@ai.net)
Date: Thu Dec 28 2000 - 12:03:25 EST


If you loop the serial port, does the port go up/up? With looped HDLC,
the interface should go up/up.

If that works, then try looping the local DSU towards the local router.
See if it goes up/up.

If it doesn't, its either a hardware problem or a setting with the DSU.

Deepak Jain
AiNET

On Thu, 28 Dec 2000, Richard Crundwell wrote:

> Can someone suggest what might be wrong with a point-to-point T1
> I'm trying to turn up. I'm running a hdlc encapsulated T1 between 2 7206's
> running 4 port serial cards. I'm using Larscom DSU's both ends one set for
> master clock internal and the other set for line. The T1 shows up end to end
> on the dsu's. ON the router interfaces we have up down on both ends. The one
> problem I see is that CTS is not up on either end. The configs on both
> interfaces are pretty straight forward. just the ip address and no ip
> directed-broadcast.
>
> Any help on why this won't come up end to end would be appreciated. I
> haven't worked much with T1 dsu's and configs.
> thanks.
> _________________________________________________________________
> Get your FREE download of MSN Explorer at http://explorer.msn.com
>
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:24 EDT