From: Edward Linta (elinta@vitts.com)
Date: Thu Dec 28 2000 - 12:22:02 EST


Try setting "dsu mode 3" for larscom dsu's

> -----Original Message-----
> From: Deepak Jain [mailto:deepak@ai.net]
> Sent: Thursday, December 28, 2000 12:03 PM
> To: Richard Crundwell
> Cc: cisco-nsp@puck.nether.net; jared@puck.nether.net
> Subject: Re: problem with point-to-point T1
>
>
>
> If you loop the serial port, does the port go up/up? With looped HDLC,
> the interface should go up/up.
>
> If that works, then try looping the local DSU towards the local router.
> See if it goes up/up.
>
> If it doesn't, its either a hardware problem or a setting with the DSU.
>
> Deepak Jain
> AiNET
>
> On Thu, 28 Dec 2000, Richard Crundwell wrote:
>
> > Can someone suggest what might be wrong with a point-to-point T1
> > I'm trying to turn up. I'm running a hdlc encapsulated T1
> between 2 7206's
> > running 4 port serial cards. I'm using Larscom DSU's both ends
> one set for
> > master clock internal and the other set for line. The T1 shows
> up end to end
> > on the dsu's. ON the router interfaces we have up down on both
> ends. The one
> > problem I see is that CTS is not up on either end. The configs on both
> > interfaces are pretty straight forward. just the ip address and no ip
> > directed-broadcast.
> >
> > Any help on why this won't come up end to end would be appreciated. I
> > haven't worked much with T1 dsu's and configs.
> > thanks.