[nsp] GSR GE packet ignores

From: Chris (anchris@cisco.com)
Date: Sun Feb 18 2001 - 23:39:46 EST


Hi all,
I have a GSR 12016 GE interface connected to Cat6k, the Cat6k spit out 1Gb
output, the GSr end is showing only appx 500-600Mb of data. The packets are
getting ignored and there is no throttles. the mode is full dulpex and auto
negotiation
enabled, have you come across any bug associated with this, is there any
work around.
I have tried to hard code the duplex setting but did not help,

here is some portion of the show tech:
GigabitEthernet2/0 is up, line protocol is up
  Hardware is GigMac GigabitEthernet, address is 0002.fc0d.5080 (bia
0002.fc0d.5080)
  Internet address is XXXX.XXXX.XXXX.XXXX
  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, rely 221/255, load 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Full-duplex mode, link type is autonegotiation, media type is LX
  output flow-control is unsupported, input flow-control is off
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:00:01, output 00:00:04, output hang never
  Last clearing of "show interface" counters 00:03:14
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  30 second input rate 609278000 bits/sec, 50372 packets/sec
  30 second output rate 1000 bits/sec, 3 packets/sec
     9639080 packets input, 1688509050 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     6374974 input errors, 0 CRC, 0 frame, 0 overrun, 6374974 ignored
     0 watchdog, 137 multicast, 0 pause input
     608 packets output, 44743 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier, 0 pause output

Thanks all,
chris



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:29 EDT