Hi all,
Please help to give some input on this issue.
I have two routers, they are connected to a switch with 10Mbps ethernet, I
have fixed the port speed at 10 on the switch. When I put in "half duplex"
on one of the port, "Single-Col Multi-Col" will increase; if the duplex
mode is "Full", " Align-Err FCS-Err" will increase. What should be the
correct setting for this ?
Felix
Port Name Status Vlan Level Duplex Speed Type
---- ------------------- ---------- ---------- ------ ------ -----
------------
2/1 connected 1 normal half 10
10/100BaseTX
Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize
---- ---------- ---------- ---------- ---------- ----------
2/1 0 0 0 0 0
Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sens Runts Giants
---- ---------- ---------- ---------- ---------- ---------- ---------
---------
2/1 54647 16078 0 0 0 0
0
=================================================
Port Name Status Vlan Level Duplex Speed Type
---- ------------------- ---------- ---------- ------ ------ -----
------------
2/2 connected 1 normal full 10
10/100BaseTX
Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize
---- ---------- ---------- ---------- ---------- ----------
2/2 32709 2286 0 0 1
Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sens Runts Giants
---- ---------- ---------- ---------- ---------- ---------- ---------
---------
2/2 0 0 0 0 0 17619
0
_________________________________________________________________________
Get Your Private, Free E-mail from MSN Hotmail at http://www.hotmail.com.
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:37 EDT