Re: [nsp] Router Reset problem

From: Scott Whyte (wwhyte@cisco.com)
Date: Wed Mar 25 1998 - 12:41:57 EST


Is it "copy sta ru" or "copy ru sta" you are doing, you have both listed
below...

On Wed, 25 Mar 1998, Michael Smith wrote:

> Hello All:
>
> I have a 7505 that, upon issuing the following commands, reboots itself with
> a Bus error. I have a case open with TAC, but they have to hunt down a
> particular programmer to decode the stac trace, and it may take several
> days.
>
> Here it is:
>
> copy tftp start
> copy start run
>
> I have about 100 PVC's on 7 serial ports and, upon issuing the copy ru sta
> portion, I get about 90 "PVC already defined" messages and then it just
> stops and reboots.
>
> We used to do configs on the router and then offload them to the tftp
> server, but I'm trying put all the configs under revision control, so I
> would prefer this method.
>
> Any help would be greatly appreciated!
>
> Mike
>
> Michael K. Smith
> Senior Network Administrator - Northwest Link
> (800) 390-1270
> http://www.nwlink.com
> mksmith@nwlink.com
>
>

-------------------------------------------------------------------
Scott Whyte swhyte@cisco.com |Any opinions expressed herein are
Network Supported Accounts (NSA) |mine and not cisco's...
CCIE 3340 |
                                 | "Eschew Obfuscation"



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:15 EDT